The EDD subpackage contains the modules that are unique to Energy Dispersive Diffraction (EDD) data processing workflows. This document describes how to run an detector energy calibration and strain analysis workflow in a Linux terminal.

Processing the data

A standard strain analysis in CHAP consists of three steps:

Activating the EDD conda environment

From the CHESS Compute Farm

Log in to the CHESS Compute Farm and activate the CHAP_edd environment:

source /nfs/chess/sw/miniforge3_chap/bin/activate
conda activate CHAP_edd

From a local CHAP clone

  1. Create and activate a base conda environent, e.g. with Miniforge.
  2. Install a local version of the CHAP package according to the instructions
  3. Create the EDD conda environment:
    mamba env create -f <path_to_CHAP_clone_dir>/CHAP/edd/environment.yml
    
  4. Activate the CHAP_edd environment:
    conda activate CHAP_edd
    

Running an EDD workflow

  1. Navigate to your work directory.
  2. Create the required CHAP pipeline file for the workflow (see below) and any additional workflow specific input files.
  3. Run the workflow:
    CHAP <pipelinefilename>
    
  4. Respond to any prompts that pop up if running interactively.

Inspecting output

The output consists of a single NeXus (.nxs) file containing the strain analysis data as well as all metadata pertaining to the analysis. Additionally, optional output figures (.png) may be saved to an output directory specified in the pipeline file.

The optional output figures can be viewed directly by any PNG image viewer. The data in the NeXus output file can be viewed in NeXpy, a high-level python interface to HDF5 files, particularly those stored as NeXus data:

  1. Open the NeXpy GUI by entering in your terminal:
    nexpy &
    
  2. After the GUI pops up, click File-> Open to navigate to the folder where your output .nxs file was saved, and select it.
  3. Navigate the filetree in the “NeXus Data” panel to inspect any output or metadata field.

Creating the pipeline file

Create a workflow pipeline.yaml file according to the instructions. A generic pipeline input file for an energy calibration and strain analysis workflow is as follows (note that spaces and indentation are important in .yaml files):

config:
  root: .           # Change as desired
  inputdir: .       # Change as desired
                    # Path can be relative to root (line 2) or absolute
  outputdir: output # Change as desired
                    # Path can be relative to root (line 2) or absolute
  interactive: true # Change as desired
  log_level: INFO

pipeline:

  # Energy calibration
  - common.SpecReader:
      config:
        station: id3a # Change as needed
        experiment_type: EDD
        spec_scans: # Edit both SPEC log file path and EDD scan numbers
                    # Path can be relative to inputdir (line 3) or absolute
          - spec_file: <your_raw_ceria_data_directory>/spec.log
            scan_numbers: 1
  - edd.MCAEnergyCalibrationProcessor:
      config:
        mask_ranges: [[650, 850]]
        max_peak_index: 1
        peak_energies: [34.276, 34.717, 39.255, 40.231]
        detectors:  # Choose the detectors
                    # Use all available detector elements when omitted
          - id: 0
          - id: 11
          - id: 22
        materials:  # Use default CeO2 properties when omitted
          - material_name: CeO2
            sgnum: 225
            lattice_parameters: 5.41153
      save_figures: true
      schema: edd.models.MCAEnergyCalibrationConfig

  # Twotheta calibration
  - pipeline.MultiplePipelineItem:
      items:
        - common.SpecReader:
            config:
              station: id3a # Change as needed
              experiment_type: EDD
              spec_scans: # Edit both SPEC log file path and EDD scan numbers
                          # Path can be relative to inputdir (line 2) or absolute
                - spec_file: <your_raw_ceria_data_directory>/spec.log
                  scan_numbers: 1
  - edd.MCATthCalibrationProcessor:
      config:
        energy_mask_ranges: [[81, 135]] # Change as needed
        detectors:  # The same as in the energy calibration when omitted
          - id: 0
          - id: 11
          - id: 22
        tth_initial_guess: 6.0
      save_figures: true

  # Create a CHESS style map
  - edd.EddMapReader:
      filename: <your_raw_data_directory>/id1a3-wbmapscan-s23-map-1.par
      dataset_id: 1
      schema: common.models.map.MapConfig
  - common.MapProcessor:
      detectors:  # Use available detector elements when omitted
        - id: 0
        - id: 11
        - id: 22

  # Perform the strain analysis
  - pipeline.MultiplePipelineItem:
      items:
        - common.YAMLReader:
            filename: tth_calibration_result.yaml
            schema: edd.models.MCATthCalibrationConfig
  - edd.StrainAnalysisProcessor:
      config:
        detectors: # Edit: Do not leave this list empty!
          - id: 0
          - id: 11
          - id: 22
        energy_mask_ranges: [[77, 110]] # Change as desired
        materials:
          - material_name: Al
            sgnum: 225
            lattice_parameters: 4.046
        rel_height_cutoff: 0.05         # Change as desired
        skip_animation: false
      save_figures: true
  - common.NexusWriter:
      filename: strain_map.nxs # Change as desired
                               # will be placed in 'outdutdir' (line 3)
      force_overwrite: true # Do not set to false!
                            # Rename an existing file if you want to prevent
                            # it from being overwritten

The “config” block defines the CHAP generic configuration parameters:

The “pipeline” block creates the actual workflow pipeline, in this example it consists of nine toplevel processes that get executed successively:

Note that the energy calibration can also be obtained ahead of time and used for multiple strain analyses. In this case remove the first four processes in the pipeline and read the detector channel energy calibration info in what is now the third item in the pipeline.

Additional notes on energy calibration

As mentioned above a standard EDD experiment needs calibration of the detector channel energies. Experiments have shown that the channel energies $E_j$ vary linearly with the channel index $j$ within the energy range of typical EDD experiments: $E_j = mj+b$, where the slope $m$ and intercept $b$ can be determined in one or a combination of two experiments:

  1. With an XRF experiment by fitting a set of flueorescence peak centers at known energies:

This uniquely determines $m$ and $b$ within the statistical errors of the experiment without having to know the actual takeoff angle $2\theta$.

  1. With a diffraction experiment by fitting a set of Bragg peak centers corresponding to known lattice spacings $d_{hkl}$:

Given Bragg’s law, $\lambda = 2d\sin(\theta)$, with $E = hc/\lambda$, the Bragg peaks appear at channels with energies $E_{hkl} = hc / (2d_{hkl}\sin(\theta)$. Rearranging this with the detector channel energy calibration relation gives:

\frac{1}{d_{hkl}} = \frac{2m\sin(\theta)}{hc} j_{hkl} + \frac{2b\sin(\theta)}{hc} = m'j_{hkl}+b'

which says that given a set of known Bragg peaks corresponding to lattice spacings $d_{hkl}$ occuring at channel indices $j_{hkl}$, a linear fit will uniquely determine $m'$ and $b'$. For a known takeoff angle $2\theta$, this uniquely determines $m$ and $b$ as well. Note that this also implies that without an accurately known value of $2theta$, one cannot uniquely determine $m$ and $b$ from Bragg diffraction alone!

This leads to the above mentioned two-step detector channel energy calibration procedure:

  1. Get nominal values for $m$ and $b$, by performing an EDD/XRF experiment on a Ce02 sample and fitting a set of fluorescence peak centers with known energies vs detector channel index.

  2. Fine tuning the calibration by fitting a set of Bragg peak centers in an EDD experiment on (typically) the same CeO2 sample, where the channel indices for the initial Bragg peak positions are obtained from the known Bragg peak energies and the nominal values for $m$ and $b$:

    • If $2\theta$ is known with sufficient accuracy, one can fit the peak centers vs detector channel index to get $m'$ and $b'$ and thus with the known $2\theta$ convert those directly to fine tuned values for $m$ and $b$ over the entire energy range of interest.

    • If $2\theta$ is not known with sufficient accuracy, one can fit the Bragg peak centers vs detector channel index to get $m$, $b$ and $2\theta$ in a way that minimizes the RMS error between the fitted peak centers for a given fit parameter set $(m, b, 2\theta)$ and those obtained from Bragg’s law given their $d_{hkl}$’s. The latter will still need a sufficently decent initial guess for $2\theta$, which can be given as an input to the CHAP $2\theta$ calibration processor or picked interactively.

The choice between the latter two apporaches is set by the calibration_method field in the $2\theta$ processor configuration in the pipeline yaml input file. Set calibration_method to direct_fit_bragg (default) to use a fixed given value of $2\theta$, or set it to direct_fit_tth_ecc to fit for the unknown $2\theta$ and the energy calibration coefficients $m$ and $b$.